THERMAL INSPECTINDOSee the Heat, Prevent the problem
Predictive thermal inspection · Indonesia

See the heat. Prevent the problem.

Certified infrared thermography for electrical and mechanical assets. We scan your equipment under normal load, find the faults the eye cannot see, and hand you a prioritised repair plan before anything trips.

Level II & III certified No shutdown required Reports with ΔT severity ranking
ISO 18436-7 · ASNTCertified thermographersLevel II and Level III on every project.
NETA MTSStandardised severityΔT criteria for consistent repair priorities.
NDT · ON-LOADZero downtimeScans run while your plant keeps producing.
INDONESIAOn-site, nationwideWe come to your facility, wherever it is.

In the field

On site. On load. On schedule.

Our thermographers work alongside your electrical team inside live panel rooms, power plant rooms and data centers, following your site's safety rules from permit to sign-off.

Equipment: FLIR E8 thermal imaging camera

Inspection team at open LV switchgear in a power plant room
Live LV switchgear · on load
Generator & power rooms

01  What we inspect

Every asset that fails hot

Loose connections, overloaded phases, failing bearings and blocked cooling all show up as heat long before they show up as downtime. We inspect the assets your operation depends on.

02  Live demo

What your eyes miss, the camera doesn't

Move the thermal lens over this distribution panel. To the eye it looks normal. Raise the load and watch a loose lug on breaker 5 turn critical.

--.-°C
IR · ε 0.95 · Trefl 30°C · LVDP-02
30°C90°C

03  Deliverable

A report your maintenance team can act on

We don't just hand over pictures. Every anomaly is documented, measured, ranked and paired with a clear corrective action.

  • ASummary of inspection

    Assets scanned, anomalies found and their priority at a glance for management.

  • BThermal and visual image pair

    So technicians find the exact component on site.

  • CTemperature, ΔT and severity

    Measured against a reference component under the same load.

  • DRecommended action

    What to repair, how urgently, and verification after the fix.

Download company brochure (PDF)↓
SAMPLE PAGE
THERMAL INSPECTINDOSee the Heat, Prevent the problem
THERMOGRAPHIC INSPECTION REPORT
REF. TI-SAMPLE-001 · PAGE 4/12

Finding 01 · LVDP-02 · MCB 5 outgoing, phase L2

IR · ε 0.95 · 3.0 m
VISUAL
Max. temp82.4 °CReference36.0 °C
ΔT46.4 °CLoad at scan80 %
SeverityCRITICAL  ΔT > 15 °C · repair immediately
ActionIsolate circuit, clean and re-terminate cable lug, torque to manufacturer specification. Re-scan under load after repair.

04  How it works

From walkdown to verified repair

A predictable process that fits around your production schedule.

STEP 1 · VISIBLE
  1. Step 1

    Survey & schedule

    We list your critical assets and agree an inspection route that fits your operations.

  2. Step 2

    On-load scan

    Panels, switchgear and machines are scanned while running at normal load.

  3. Step 3

    Analysis & report

    Each anomaly gets thermal and visual images, ΔT, severity and a recommended action.

  4. Step 4

    Repair & verify

    After your team repairs, we re-scan to confirm the problem is gone.

05  Service packages

Annual contracts, predictable cost

Regular inspections cost significantly less than ad-hoc call-outs, and every scan builds on the last.

My facility is
Package BasicANNUAL ProBI-ANNUAL PremiumQUARTERLY
Inspection frequency1× / year2× / year4× / year
Detailed analysis report✓✓✓
Historical trend data——✓
Best forOffice / RetailLight factoryHeavy industry / Data center
Request quote Request quote Request quote

06  Your thermographers

Certified people, not just cameras

Every inspection is carried out and signed off by a certified thermographer you can talk to directly.

KP
Certified Level II Thermographer

Kris Priatmoko

MA
Certified Level III Thermographer

Matheus Adi

07  FAQ

Common questions

Do you need to shut down our equipment?

No. Thermography only works when equipment is energised and carrying load, so we inspect during normal operation. We only need safe access to open panel covers, accompanied by your authorised personnel.

What equipment can you inspect?

LV and MV switchgear, distribution panels, MCCs, transformers, busbars, cables and terminations, motors, bearings, couplings, UPS and battery systems, and solar PV installations.

What do we receive after the inspection?

A written report with a summary of inspection, thermal and visual images for every anomaly, measured temperatures, ΔT, severity ranking and recommended corrective actions.

How long does an inspection take?

It depends on the number of panels and machines. After a short survey we confirm the schedule so it fits around your production.

Is the demo inspection really free?

Yes. We inspect a sample of your critical equipment at no cost so you can see the findings and the report format before committing to a package.

08  Contact

Don't wait for a failure to happen

Tell us about your site and we will schedule a free demo thermal inspection.

WhatsApp+62 813-9077-8856
Office · SemarangOn-site across Indonesia

Perum Klipang Pesona Asri 3 Blok G No. 9D, Semarang, Jawa Tengah

Open in Google Maps
Chat with us